Line pressure (1) regulated by the regulator valve flows to the shift solenoid valves The PCM switches the shift solenoid valves ON and OFF The conditions of the shift solenoid valves and the positions of the shift valves are as follows

Line pressure (1) also flows to the modulator valve and becomes modulator pressure (6) Modulator pressure (6) flows to the A/T clutch pressure control solenoid valves The manual valve covers the port leading pressure to the clutches, and hydraulic pressure is not applied to the clutches

NOTE: When used, "left" or "right" indicates direction on the hydraulic circuit
Fig 1: Hydraulic Pressure Flow Diagram - N Position
G05990620Courtesy of AMERICAN HONDA MOTOR CO., INC.