Brad's Car Manuals: A 3rd party mirror of CHARM + LEMON car manuals
Home >> Ford >> 1997 >> Probe Base, Automatic >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System - Generator >> On-Vehicle Testing >> Amperage Output Test

Amperage Output Test

Download the full database via torrent (~1.1 TB)  |  Custom patches
  1. Ensure drive belt is in good condition and properly tightened. Connect charging system load tester in accordance with manufacturer's instructions. Start and run engine at 2000-3000 RPM and apply load until generator output levels off.
  2. Record maximum generator output current. See GENERATOR OUTPUT SPECIFICATIONS TABLE for output values. If generator output is 10- 20 percent of rated output amperage, generator output is okay. If generator does not produce rated output, go to VOLTAGE OUTPUT TEST .
GENERATOR OUTPUT SPECIFICATIONS

Application Amps Rating
2.0L 80
2.5L 90