  1. Remove diode (rectifier) assembly from generator. Check continuity of each diode in both directions by reversing test probes between diode terminals. See Fig 1 . To test all 9 diodes, perform continuity checks between terminal "B" and each "P" terminal, terminal B1 and each "P" terminal, and terminal "E" and each "P" terminal.
  2. All diodes should show continuity in one direction and no continuity in the opposite direction. If any diode does not test as specified, replace diode (rectifier) assembly.
Fig 1: Testing Diode (Rectifier) Assembly (Mitsubishi)
G97H11053Courtesy of AMERICAN HONDA MOTOR CO., INC.