Remove temperature sender. Using hot water to warm the sending unit, measure resistance readings while warming up sending unit. Resistance readings should be 90-117.5 ohms at 158°F (70°C) and 21.3-26.3 ohms at 239°F (115°C).

Fig 1: Testing Coolant Temperature Sending Unit
G90A02711Courtesy of HYUNDAI MOTOR CO.