Brad's Car Manuals: A 3rd party mirror of CHARM + LEMON car manuals
Home >> Lexus >> 2003 >> LS 430 >> Repair and Diagnosis >> Electrical >> Starter >> Starting (Service Specifications) >> Service Data

Service Data

Download the full database via torrent (~1.1 TB)
STARTING COMPONENTS SERVICE SPECIFICATION

Starter Rated voltage and output power 12 V 2.0 Kw
No-load characteristics
  1. Current
  2. rpm
  1. 100 A or less at 11.5 V
  2. 2,500 rpm or less
Brush length
  1. STD
  2. Minimum
  1. 15.0 mm (0.591 in.)
  2. 9.0 mm (0.354 in.)
Spring installed load
  1. STD
  2. Minimum
  1. 21.5 - 27.5 N (2.2 - 2.8 kgf, 4.9 - 6.2 lbf)
  2. 12.7N (1.3kgf, 2.9lbf)
Commutator
Diameter
  1. STD
  2. Minimum
  1. 35.0 mm (1.378 in.)
  2. 34.0 mm (1.339 in.)
Undercut depth
  1. STD
  2. Minimum
  3. Circle runout Maximum
  1. 0.7 mm (0.028 in.)
  2. 0.2 mm (0.008 in.)
  3. 0.05 mm (0.0020 in.)
Magnetic switch
Contact plate for wear Maximum
0.9 mm (0.035 in.)