Brad's Car Manuals: A 3rd party mirror of CHARM + LEMON car manuals
Home >> Mazda >> 2002 >> MPV V6-3.0L DOHC >> Repair and Diagnosis >> Body and Frame >> Locks >> Power Locks >> Power Door Lock Control Module >> Testing and Inspection

Power Door Lock Control Module: Testing and Inspection

Download the full database via torrent (~1.1 TB)  |  Download Brad's custom LEMON patches
DOOR LOCK CONTROL MODULE INSPECTION

Terminal Voltage Table (Reference) Part 1:




Terminal Voltage Table (Reference) Part 2:




1. Measure the voltage at the door lock control module terminals as indicated.
2. Disconnect the door lock control module connector before inspecting for continuity at terminals F, H, M, and N.
- If not as specified, inspect the parts listed under "Action."
- If the parts and wiring harnesses are okay but the system still does not work properly, replace the door lock control module.