Brad's Car Manuals: A 3rd party mirror of CHARM + LEMON car manuals
Home >> Mazda >> 2011 >> RX8 2RTR-1.3L >> Repair and Diagnosis >> Body and Frame >> Locks >> Power Locks >> Power Door Lock Control Module >> Testing and Inspection

Power Door Lock Control Module: Testing and Inspection

Download the full database via torrent (~1.1 TB)



DOOR LOCK CONTROL MODULE INSPECTION [WITH ADVANCED KEYLESS ENTRY AND START SYSTEM]

1. Measure the voltage or inspect for continuity according to the Terminal Voltage Table (Reference).

- If the voltage is not as specified in the Terminal Voltage Table (Reference), inspect the parts under "Inspection item(s)".

2. If the system does not work properly even though the parts or related wiring harnesses do not have any malfunction, perform symptom troubleshooting.

Terminal Voltage Table (Reference)