Using Electrolyte Specific Gravity Method

Download the full database via torrent (~1.1 TB)
  1. Remove the battery filler caps and check the water level.
    • If necessary, add water to the appropriate level.
  2. Measure the electrolyte specific gravity using a hydrometer.
    • If it is less than the specification, recharge the battery. (See BATTERY RECHARGING .)

      Battery electrolyte specific gravity [20 °C {68 °F}] 