Brad's Car Manuals: A 3rd party mirror of CHARM + LEMON car manuals
Home >> Saturn >> 2000 >> SW2 Automatic >> Repair and Diagnosis >> Engine Performance >> Theory and Operation >> Engine Control System - Theory & Operation >> Computerized Engine Controls >> Input Devices >> Generator "L" Light Circuit

Generator "L" Light Circuit

Download the full database via torrent (~1.1 TB)  |  Download Brad's custom LEMON patches

On models where generator is controlled by the PCM, PCM can use the "L" circuit to control generator operation during starting. If PCM is disabling the generator, scan tool will display ACTIVE, or when the disable operation of generator is active. PCM also supplies about 5 volts through the "L" circuit to generator. If generator becomes inoperative, PCM senses the fault through the "L" circuit and commands the Instrument Panel Circuit (IPC) to illuminate the VOLTS light.