  1. POWER WINDOW REGULATOR MOTOR ASSEMBLY (LH AND RH) 
    1. Reset the power window regulator motor (See INITIALIZATION  ).
    2. Check if the power window AUTO UP/DOWN function operates normally.

      OK: 

      AUTO UP/DOWN function operates normally. 

    NG: OTHER PROBLEM 

    OK: Go to next step 

  2. CHECK JAM PROTECTION FUNCTION OPERATING RANGE 
    1. Check that the jam protection function operates normally (See ON-VEHICLE INSPECTION  ).

      HINT:

      The jam protection function does not operate from the fully closed position of the door glass to 4 mm (0.16 in.) below that.

    NG: REPLACE POWER WINDOW REGULATOR SWITCH ASSEMBLY (LH AND RH) 

    OK: END