  1. RESET POWER WINDOW REGULATOR MOTOR ASSEMBLY (LH AND RH) 
    1. Reset the power window regulator motor for the power window that does not fully close (See INITIALIZATION  ).
    2. Check if the window AUTO UP/DOWN function operates normally.

      OK: 

      AUTO UP/DOWN function operates normally. 

    OK: END 

    NG: Go to next step 

  2. CHECK FRONT DOOR WINDOW REGULATOR SUB-ASSEMBLY (LH AND RH) 
    1. Remove the door glass ( COMPONENTS ).
    2. Operate the power window regulator without installing the door glass using the power window switch.
    3. Check that the power window regulator operates smoothly.

      OK: 

      Power window regulator operates smoothly. 

    NG: REPLACE FRONT DOOR WINDOW REGULATOR SUB-ASSEMBLY (LH AND RH) 

    OK: REPLACE DOOR GLASS RUN (LH AND RH)