Load Test

Download the full database via torrent (~1.1 TB)
  1. Using proper starter bench tester, apply 3.5 ft. lbs. (4.7 N.m) load to starter. Engage tester switch for less than 30 seconds. Note and record voltage drop and current draw.
  2. Voltage should not fall below 8 volts. Current draw should be less that 200 amps. Starter should spin at 1200 RPM or more.