Brad's Car Manuals: A 3rd party mirror of CHARM + LEMON car manuals
Home >> Subaru >> 1994 >> Legacy Alpine >> Repair and Diagnosis >> Electrical >> Starter >> Bench Testing >> Solenoid Tests >> Solenoid Pull-In Test

Solenoid Pull-In Test

Download the full database via torrent (~1.1 TB)  |  Download Brad's custom LEMON patches

Connect jumper wire from negative terminal of 12-volt battery to starter solenoid case. Connect another jumper wire from negative terminal of 12-volt battery to terminal "C". See Fig 1 . Pinion should extend when jumper wire from battery positive terminal is connected to solenoid terminal No. 50. If pinion does not extend as specified, replace starter.

Fig 1: Testing Starter Solenoid Pull-In & Hold-In Windings
G91J01160Courtesy of SUBARU OF AMERICA, INC.