Brad's Car Manuals: A 3rd party mirror of CHARM + LEMON car manuals
Home >> Subaru >> 1999 >> Forester Base >> Repair and Diagnosis >> Electrical >> Charging Systems >> Generators & Regulators >> Overhaul

Generators & Regulators: Overhaul

Download the full database via torrent (~1.1 TB)  |  Download Brad's custom LEMON patches
NOTE: See Fig 1 for exploded view of generator.

To remove a stuck rear cover after removing case bolts, use soldering iron or heat gun to warm rear cover bearing housing to about 122-140°F (50-60°C). This will expand housing enough to slide cover off rotor bearing. Ensure spring washer located in rear cover bearing bore is not lost during disassembly.

Fig 1: Exploded View Of Mitsubishi Generator (Typical)
G96D07201Courtesy of SUBARU OF AMERICA, INC.