  1. Clamp starter in starter bench tester. Connect test equipment to starter. See Fig 1. Close switch to engage starter. Measure current draw, rotating speed, and voltage drop. See STARTER SPECIFICATIONS .
  2. Low rotating speed or excessive current draw may be caused by high friction rotating resistance because of worn bushings or improper assembly.
Fig 1: Testing Starter No-Load Performance (Typical)
G91F01158Courtesy of SUBARU OF AMERICA, INC.