Brad's Car Manuals: A 3rd party mirror of CHARM + LEMON car manuals
Home >> Suzuki >> 2001 >> Swift GL, Automatic >> Repair and Diagnosis >> Electrical >> Charging Systems >> Generators & Regulators >> Bench Testing >> Rectifier >> Swift & Vitara

Swift & Vitara

Download the full database via torrent (~1.1 TB)  |  Download Brad's custom LEMON patches
  1. Connect ohmmeter leads between upper and lower rectifier bodies and each diode lead. Note continuity reading. Perform STEP 1. See Fig 1 .
  2. Reverse ohmmeter leads and note continuity reading. Continuity should exist with ohmmeter leads in one direction, and no continuity should exist when ohmmeter leads are reversed. Replace rectifier if continuity is not as specified. See OVERHAUL  .
  3. Connect ohmmeter leads between both ends of diode trio on rectifier and note continuity reading. Perform STEP 2. See Fig 1 .
  4. Reverse ohmmeter leads and note continuity reading. Continuity should exist with ohmmeter leads in one direction, and no continuity should exist when ohmmeter leads are reversed. Replace rectifier if continuity is not as specified. See OVERHAUL  .
Fig 1: Testing Rectifier (Swift & Vitara)
G96G11292Courtesy of SUZUKI OF AMERICA CORP.