  1. To test rotor for an open circuit, use ohmmeter to check for continuity between slip rings of rotor. If there is no continuity, replace the rotor "1". See Fig 1 .
  2. Using ohmmeter, check that there is no continuity between slip ring and rotor core. If there is continuity, replace rotor "1". See Fig 1 .
  3. Check slip rings for roughness or scoring. If rough or scored, replace the rotor.
  4. Using a vernier caliper, measure the slip ring diameter. If the diameter is less than minimum, replace the rotor (80A/105A). See Fig 2 .
Fig 1: Testing Rotor For Open Or Grounded Circuits
G96G10716Courtesy of SUZUKI OF AMERICA CORP.
Fig 2: Measuring Slip Ring Diameter (80A/105A)