Brad's Car Manuals: A 3rd party mirror of CHARM + LEMON car manuals
Home >> Toyota >> 2007 >> Prius Base >> Repair and Diagnosis >> Body & Frame >> Windows >> Windshield/WINDOWGLASS >> Power Window Control System >> Auto Up Operation does not Fully Close Power Window (Jam Protection Function is Activated) >> Inspection Procedure

Inspection Procedure

Download the full database via torrent (~1.1 TB)  |  Download Brad's custom LEMON patches
  1. RESET POWER WINDOW REGULATOR MOTOR FRONT LH 
    1. Reset the power window regulator motor (see INITIALIZATION ).
    2. Check that the power window AUTO UP / DOWN function operates normally.

      OK : AUTO UP / DOWN function operates normally. 

    OK : END 

    NG : GO TO NEXT STEP 

  2. CHECK POWER WINDOW REGULATOR ASSEMBLY LH 
    1. Remove the door glass (See DISASSEMBLY ).
    2. Operate the front door window regulator using the switch.
    3. Check that the power window regulator operates smoothly.

      OK : Power window regulator operates smoothly. 

    NG : REPLACE POWER WINDOW REGULATOR ASSEMBLY LH 

    OK : REPLACE DOOR GLASS RUN